MixRite seals are a wear item. Tefen’s guides for the MixRite 2.5, 3.5, LF-1000 and TF5 all put seal replacement at once a year, and the 2.5 and 3.5 seal kit guides add that it depends on how much the pump runs. Change them sooner if the pump stutters at low flow or struggles to draw additive. This guide covers when to change them, what to check first, how the job goes and how to get the right kit.
Short answer: replace MixRite seals once a year, or sooner if the pump stutters at low flow or suction is irregular. A seal change takes ten minutes, and Dosing Systems Australasia (DSA) holds seal kits and spares for the MixRite models in the trade-in.
How often should MixRite seals be replaced?
Tefen’s user guides for the MixRite 2.5, LF-1000 and TF5 list seal replacement as a yearly job, and the TF25 manual says every 12 months. The 2.5 and 3.5 seal kit guides add that the timing depends on usage.
| MixRite model | Seal replacement | Where to look |
|---|---|---|
| 2.5 | Yearly, based on usage | Tefen 2.5 seal kit guide and user manual |
| 3.5 | Yearly, based on usage | Tefen 3.5 seal kit guide for your ratio range |
| LF-1000 | Yearly | Tefen LF-1000 user guide |
| TF5 | Yearly | Tefen TF5 user guide |
| TF10 | Not stated in the TF10 manual | Your manual, or ask DSA or your Tefen supplier |
| TF25 | Every 12 months | Tefen TF25 manual |
Change the seals sooner if you see either of these:
- The pump stutters, or does not run at all, at low flow.
- Suction is irregular, or the pump is not drawing additive.
If you run the pump hard through summer, the yearly job is worth doing before the season starts rather than after. For any other model, including the MixRite TF10, check the manual that came with your pump, or reach out to us or your Tefen supplier.
What should I check before replacing MixRite seals?
Irregular suction is not always a seal problem. Rule out the simple causes first:
- Clean the water filter at the pump inlet and the suction filter on the additive line.
- Let trapped air out through the air release valve at the top of the pump.
- Rinse the pump with clean water after use. Tefen recommends this to keep the pump in good condition, and it matters most with soluble products.
If the filters are clean and the symptoms stay, the seals are the next thing to look at. If you run into any issues along the way, contact us directly on (02) 4329 0905 or sales@dosingsystems.com.au.
How do you replace the seals on a MixRite?
Every MixRite ships with installation instructions, and Tefen publishes a seal kit replacement guide for each model and ratio version, some with a video. The outline below shows the general order of the job. A seal change takes ten minutes, so you can get back to what you’re doing sooner. Follow the guide for your pump for the detail.
- Turn off the water supply and make sure there is no pressure in the line.
- Remove the top cover, release the hose nut and take off the suction tube.
- Take the pump apart as your guide shows, and keep the piston clean.
- Replace the seals in your kit. Most MixRite models use an engine top seal, an engine bottom seal and a suction seal, and some 3.5 ratio versions add a conical seal. Check each seal’s orientation before it goes in. On the 2.5 the wide side faces up.
- Fit the seals by hand, without tools. If a seal is stiff, soften it in hot water first.
- Apply silicone grease to the top and bottom engine seals.
- Reassemble, turn the water back on and check the pump starts and doses.
How do I get the right MixRite seal kit?
Seal kits are model specific. Tefen publishes separate guides for the MixRite 2.5 and 3.5 and for each ratio range. Chlorine (CL) versions use chlorine-resistant seals and PVDF versions are acid-duty, so match the kit to your version. Our chemical compatibility guide and the MixRite and Hydro Systems range guide help you check which version you have.
Have your model and ratio range ready when you ask for a kit. If you are not sure, send us a photo of the pump and we will identify it.
We keep seal kits and spares on the shelf for the MixRite models in the trade-in: the 2.5, 3.5, LF-1000 and TF range. See our spare parts and service kits page, or our equipment servicing page if you would rather we handle the job. For other models, reach out to us or your Tefen supplier.
Running an older Dosatron?
If you have a Dosatron that is past a seal change, the DSA trade-in includes a free seal kit with your new Tefen MixRite. Until 31 December 2026, trade in any Dosatron pump, working or not, and take up to $400 off a Tefen MixRite with code TRADETRON26, up to 10 units per customer. Return the old unit within 30 days of delivery. The model-by-model chart and the full terms are on the trade-in offer page.
Dosatron is a trade mark of its owner. Dosing Systems Australasia is not affiliated with Dosatron or its distributors.
Frequently asked questions
How often should MixRite seals be replaced?
Tefen’s guides for the MixRite 2.5, 3.5, LF-1000 and TF5 put seal replacement at once a year, and the 2.5 and 3.5 seal kit guides add that it depends on usage. For other models, check the manual that came with your pump, or reach out to us or your Tefen supplier.
What are the signs a MixRite needs new seals?
The pump stutters or does not run at low flow, or suction is irregular or missing. Rule out a blocked water filter, a blocked suction filter and trapped air first.
Do I need a technician to change MixRite seals?
DSA’s product catalogue says no technician is needed to change spare parts, and each unit ships with instructions. Follow the guide for your model.
How long does a MixRite seal change take?
A seal change takes ten minutes. Follow the Tefen guide for your model and ratio range.
How do I know which MixRite seal kit I need?
It depends on your model and ratio range, and on whether you have a chlorine (CL) or PVDF version. Send us your model details, or a photo of the pump, and we will confirm the kit.
What if my MixRite model is not listed here?
Check the manual that came with your pump, or reach out to us or your Tefen supplier. We are happy to point you to the right guide.
Is a seal kit included with the DSA trade-in?
Yes. A free seal kit is included when you trade in a Dosatron pump for a Tefen MixRite under the offer, which runs until 31 December 2026.
Tefen guides for your model
The manufacturer’s own guides, if you want the full detail for your pump:
- MixRite 2.5 seal kit replacement guide (0.4 to 4%)
- MixRite 3.5 seal kit replacement guide (0.03 to 0.2%)
- MixRite 3.5 seal kit replacement guide (0.5 to 5%)
- MixRite 3.5 seal kit replacement guide (1 to 10%)
- MixRite LF-1000 user guide
- MixRite TF5 user guide
Need a kit, or a hand with the job?
Call (02) 4329 0905, email sales@dosingsystems.com.au or request a quote. If you are still choosing a pump, read our guide to choosing a water-driven dosing pump.
This article is general guidance only. Follow the Tefen guide for your model and confirm the right kit with DSA before you order.